Placement of Electroless Nickel Plating Production Line
Today, the author will introduce you to chemical platingnickelThe placement of the production line, the placement of the electroless nickel plating production line should be based on the ease of operation as the first standard.
Place the production equipment in the order of the established production process. The deionized water bucket and the refilling solution should be close to the plating tank. The plating tank should have a corresponding distance from the left and right front and post-processing areas. The finished product accumulation area should be placed in another room as much as possible. , to prevent acid mist from eroding steel parts.
All power cords should be covered with rubber sleeves, and do not need to be placed on the road to prevent frequent footsteps, squeezing, causing the coat to crack and leak electricity. The ventilation equipment should be at a height of about 2 meters from the road. , Exhaust equipment should be installed near the drying tank.
Pure water equipment, air compressors and some auxiliary mechanical equipment should be placed in the room next to the production line as much as possible. Nowadays, most electroless nickel plating solutions are acetic acid buffer system, and the complexing agent is also based on lactic acid-citric acid system, so acid gas is relatively Heavy, it will erode the machinery and equipment greatly. If there is traffic in the production line, you must pay attention to painting and maintaining architectural coatings. Measure the volume inside the production workshop, and allocate the exhaust equipment of the production workshop. The production laboratory is as close as possible to Each production line is in a better spacing.